Ultra-Low-Dose Of CT In 3D Printing Models Good Enough To Diagnose Wrist Fractures

The introduction of CT in the early 1970s provided orthopaedic surgeons with a method of imaging that could be used to characterise a fracture more completely than by conventional radiography alone.
Today, CT scanning is used routinely in the evaluation of specific fractures. A research team of Guangdong Hospital of Traditional Chinese Medicine, China recently found that an ultralow-dose CT protocol yielded 97% lower radiation dose and enabled the production of 3D-printed models that were deemed equivalent to those manufactured from standard-dose images for distal radial fractures. The research findings were published in the European Journal of Radiology on December 29, 2020.
CT has several advantages, including the ability to characterise a fracture in greater detail, to identify an occult fracture, and to diagnose incomplete union, all of which have practical implications for treatment of the individual patient. For these reasons, the number of CT scans performed annually has increased dramatically. Bone injuries can be treated using tissue engineering scaffolds, but the conventional constructs have a big challenge in supplying requirements of native tissue, i.e., bioactivity potential, mechanical stability, controllable biodegradability, and proper cellular interaction. In this regard, 3D printing technology with the possibility of controlling the internal microstructure and geometry of synthesized matrixes was introduced as a promising approach for bone defect regeneration. However, the effects of low-dose CT techniques on 3D printing have been unknown. Therefore, the researchers conducted a study to explore the effect of ultra-low-dose computed tomography (CT) on three-dimensional (3D) printing models and the diagnosis of wrist fractures.
They enrolled a total of 76 consecutive patients with clinical suspicion of distal radial fractures (DRFs). All individuals had undergone 320-row detector CT and researchers randomly divided them into Group A (n=38) that received unenhanced CT scans at standard-dose (120 kV and 100 mA) and Group B (n=38) that received ultralow-dose (80 kV and 10 mA) protocols on an Aquilion One CT scanner. For objective image quality assessment, they measured the noise, CT number, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Two orthopaedic surgeons blinded to the scan parameters evaluated the clarity of the 3D printing model and fracture line using a 3-point scale. Researchers also calculated the mean radiation dose and compared diagnostic performances for the fractures between the two groups.
They found that the effective radiation dose was significantly reduced by 97.1 % in Group B when compared with Group A. They also found the Quantitative objective image quality parameters (e.g., CNR, SNR, and CT numbers) were higher in the standard-dose group. However, they found no difference in subjective scoring of the 3D printing model. Although the fracture line score was higher in Group A they noted a consistent diagnostic performance in both the groups. They observed no significant differences in the sensitivity, specificity or accuracy between standard-dose group and ultra-low-dose group.
The authors concluded, "The ultra-low-dose protocol effectively reduced the radiation dose by 97.1 %, while maintaining the image quality for the diagnosis of DRFs. Therefore, this protocol can meet the needs of 3D printing models for preoperative assessments".
For further information:
DOI: https://doi.org/10.1016/j.ejrad.2020.109488

Disclaimer: This website is designed for healthcare professionals and serves solely for informational purposes.
The content provided should not be interpreted as medical advice, diagnosis, treatment recommendations, prescriptions, or endorsements of specific medical practices. It is not a replacement for professional medical consultation or the expertise of a licensed healthcare provider.
Given the ever-evolving nature of medical science, we strive to keep our information accurate and up to date. However, we do not guarantee the completeness or accuracy of the content.
If you come across any inconsistencies, please reach out to us at admin@doctornewsdaily.com.
We do not support or endorse medical opinions, treatments, or recommendations that contradict the advice of qualified healthcare professionals.
By using this website, you agree to our Terms of Use, Privacy Policy, and Advertisement Policy.
For further details, please review our Full Disclaimer.

0 Comments

Post a comment

Please login to post a comment.

No comments yet. Be the first to comment!