Totally magnetic technique effective option for sentinel lymph node detection and breast cancer localization suggests a new study published in the JAMA Surgery
Guidewires have been the standard for breast lesion localization but pose operative and logistic challenges. Paramagnetic seeds have shown promising results, but to the authors’ knowledge, no randomized comparison has been performed.
A study was done to determine whether the combination of a paramagnetic seed and superparamagnetic iron oxide (SPIO) is equivalent to guidewire and SPIO for breast cancer localization and sentinel lymph node detection (SLND).
This was a phase 3, pragmatic, equivalence, 2-arm, open-label, randomized clinical trial conducted at 3 university and/or community hospitals in Sweden from May 2018 to May 2022. Included in the study were patients with early breast cancer planned for breast conservation and SLND. Study data were analyzed July to November 2022.
Participants were randomly assigned 1:1 to a paramagnetic seed or a guidewire. All patients underwent SLND with SPIO.
Results
A total of 426 women were included in the study. The re-excision rate was 2.90%, and the median (IQR) resection ratio was 1.96 (1.15-3.44). No differences were found between the guidewire and the seed in re-excisions (6 of 211 [2.84%] vs 6 of 209 [2.87%]; difference, −0.03%; 95% CI, −3.20% to 3.20%; P = .99) or resection ratio (median, 1.93; IQR, 1.18-3.43 vs median, 2.01; IQR, 1.11-3.47; P = .70). Overall SLN detection was 98.6% (95% CI, 97.1%-99.4%) with no differences between arms (203 of 207 [98.1%] vs 204 of 206 [99.0%]; difference, −0.9%; 95% CI, −3.6% to 1.8%; P = .72). More failed localizations occurred with the guidewire (21 of 208 [10.1%] vs 4 of 215 [1.9%]; difference, 8.2%; 95% CI, 3.3%-13.2%; P < .001). Median (IQR) time to specimen excision was shorter for the seed (15 [10-22] minutes vs 18 [12-30] minutes; P = .01), as was the total operative time (69 [56-86] minutes vs 75.5 [59-101] minutes; P = .03). The experience of surgeons, radiologists, and surgical coordinators was better with the seed.
The combination of SPIO and a paramagnetic seed performed comparably with SPIO and guidewire for breast cancer conserving surgery and resulted in more successful localizations, shorter operative times, and better experience.
Reference
Pantiora E, Jazrawi A, Hersi A, et al. Magnetic Seed vs Guidewire Breast Cancer Localization With Magnetic Lymph Node Detection: A Randomized Clinical Trial. JAMA Surg. Published online December 27, 2023. doi:10.1001/jamasurg.2023.6520
Keywords:
Totally, magnetic, technique, effective, option, for, sentinel, lymph, node, detection, and, breast, cancer, localization, Pantiora E, Jazrawi A, Hersi A, JAMA Surgery

Disclaimer: This website is designed for healthcare professionals and serves solely for informational purposes.
The content provided should not be interpreted as medical advice, diagnosis, treatment recommendations, prescriptions, or endorsements of specific medical practices. It is not a replacement for professional medical consultation or the expertise of a licensed healthcare provider.
Given the ever-evolving nature of medical science, we strive to keep our information accurate and up to date. However, we do not guarantee the completeness or accuracy of the content.
If you come across any inconsistencies, please reach out to us at admin@doctornewsdaily.com.
We do not support or endorse medical opinions, treatments, or recommendations that contradict the advice of qualified healthcare professionals.
By using this website, you agree to our Terms of Use, Privacy Policy, and Advertisement Policy.
For further details, please review our Full Disclaimer.

0 Comments

Post a comment

Please login to post a comment.

No comments yet. Be the first to comment!