November 02, 2025

Get In Touch

Subtle Variations In Contour Of Single-Crown Implant Restorations May Impact Biofilm Accumulation And Mucosal Inflammation

Study on Implant Restorations

Impact of Contour Variations in Single-Crown Implant Restorations

Subtle variations in contour of single-crown implant restorations may impact biofilm accumulation and mucosal inflammation suggests a new study published in the Clinical Oral Implants Research.

The shape of implant restorations is critical for function and aesthetics. It may also be important in peri-implant tissue health preservation. This study aimed to associate the restorative contour of a single crown with marginal dental plaque accumulation, tissue inflammation, and probing depths.

Methodology

Subjects with a single screw-retained implant restoration were clinically examined. The presence of dental biofilm, tissue inflammation, and probing pocket depths were the dependent variables. The emergence angle, profile, and depth of the mucosal tunnel were measured on superimposed digital scans of the crown soft-tissue complex, the removed crown mounted on an analogue, and the soft tissue.

Results

One hundred twenty-two subjects (46.7% female, 68.9% never smokers, 77% with treated periodontitis, and 52.5% participating in regular supportive peri-implant care) were examined. The emergence angles at the mucosal margin were 15.3 ± 9.4°, 12.7 ± 8.5°, 31.3 ± 11.8°, and 19.2 ± 9.8° for the mesial, distal, vestibular, and oral aspects of the crowns. The largest emergence profile angles were observed on the vestibular aspect (74.6% of cases), reaching a maximum of 61.7°, and profiles were convex in 59% of cases. Generalized estimating equations indicated that the site-specific platform-level emergence angle and profile and depth of the mucosal tunnel were significantly associated with the presence of detectable plaque accumulation (p < .01) and bleeding on probing (p < .02).

Subtle variations in the shape of the restorative crown are associated with biofilm accumulation and mucosal inflammation. These findings are important for 3D implant planning/positioning and preservation of peri-implant tissue health.

Reference

Pelekos, G., Chin, B., Wu, X., Fok, M. R., Shi, J., & Tonetti, M. S. (2023). Association of crown emergence angle and profile with dental plaque and inflammation at dental implants. Clinical Oral Implants Research, 00, 1–11. https://doi.org/10.1111/clr.14134

Keywords

  • Clinical Oral Implants Research
  • Pelekos, G.
  • Chin, B.
  • Wu, X.
  • Fok, M. R.
  • Shi, J.
  • Tonetti, M. S.
  • Association
  • Crown
  • Emergence
  • Angle
  • Profile
  • Dental
  • Plaque
  • Inflammation
  • Dental Implants

Disclaimer: This website is designed for healthcare professionals and serves solely for informational purposes.
The content provided should not be interpreted as medical advice, diagnosis, treatment recommendations, prescriptions, or endorsements of specific medical practices. It is not a replacement for professional medical consultation or the expertise of a licensed healthcare provider.
Given the ever-evolving nature of medical science, we strive to keep our information accurate and up to date. However, we do not guarantee the completeness or accuracy of the content.
If you come across any inconsistencies, please reach out to us at admin@doctornewsdaily.com.
We do not support or endorse medical opinions, treatments, or recommendations that contradict the advice of qualified healthcare professionals.
By using this website, you agree to our Terms of Use, Privacy Policy, and Advertisement Policy.
For further details, please review our Full Disclaimer.

0 Comments

Post a comment

Please login to post a comment.

No comments yet. Be the first to comment!