Proanthocyanidin Protects Enamel Against Initial Erosions, Study Finds
- byDoctor News Daily Team
- 29 July, 2025
- 0 Comments
- 0 Mins
Recent research published in the American Journal of Dentistry has revealed that Proanthocyanidin protects the enamel against initial erosive challenge when applied over acquired pellicle.
Concurrently with the growing interest in CAD-CAM systems, several new materials of different chemical nature have become available. As an alternative to ceramics, numerous polymer-based materials have recently been proposed for permanent prosthetic restorations.
Hence, Ana Paula Boteon and colleagues from the Department of Restorative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil conducted the study to test the CAD-CAM polymer-based materials available on the market, comparing mean flexural strength, Weibull characteristic strength and Weibull modulus.
The authors tested seven different types of polymer-based blocks. These included- Lava Ultimate, 3M; Brilliant Crios, Coltene; Cerasmart, GC; Block HC, Shofu; Katana Avencia, Noritake; Grandio Blocs, Voco; Tetric CAD, and Ivoclar-Vivadent. Specimens were cut out from blocks, finished, polished, and tested in a three-point bending test apparatus until failure (n=30). Flexural strength, Weibull characteristic strength, and Weibull modulus was calculated. Flexural strength data were statistically analyzed. ANOVA on Ranks was applied, followed by Dunn's test for post hoc comparisons (P= 0.05).
The findings were-
a. Different letters in parentheses label statistically significant differences: Grandio Blocs 266±24(a), Brilliant Crios 259±21(ab); Tetric CAD 254±15(ab); Katana Avencia 241±29(bc); Cerasmart 221±24(cd); Lava Ultimate 196±23(de); Block HC 139±10(e).
b. All the tested materials had flexural strengths greater than 100 MPa, thereby satisfying the requirements of ISO standards for polymer-based materials.
c. For all the tested materials the Weibull characteristic strength was greater than 100 MPa. Weibull modulus ranged between 21.20 (Tetric CAD) and 9.09 (Katana Avencia).
Hence, the team concluded that "even though all the CAD-CAM polymer-based materials marketed in blocks tested in the present study satisfies the requirements of ISO standard for polymer-based materials, their flexural resistance differs significantly. The data presented in the study may be helpful to clinicians for selecting the most appropriate materials for each clinical case."
Disclaimer: This website is designed for healthcare professionals and serves solely for informational purposes.
The content provided should not be interpreted as medical advice, diagnosis, treatment recommendations, prescriptions, or endorsements of specific medical practices. It is not a replacement for professional medical consultation or the expertise of a licensed healthcare provider.
Given the ever-evolving nature of medical science, we strive to keep our information accurate and up to date. However, we do not guarantee the completeness or accuracy of the content.
If you come across any inconsistencies, please reach out to us at
admin@doctornewsdaily.com.
We do not support or endorse medical opinions, treatments, or recommendations that contradict the advice of qualified healthcare professionals.
By using this website, you agree to our
Terms of Use,
Privacy Policy, and
Advertisement Policy.
For further details, please review our
Full Disclaimer.
Recent News
Eli Lilly plans to build new USD 3 billion facilit...
- 04 November, 2025
Rajkot Maternity Hospital CCTV Leak: How a simple...
- 04 November, 2025
Gland Pharma profit rises 12 percent to Rs 184 cro...
- 04 November, 2025
Daily Newsletter
Get all the top stories from Blogs to keep track.
0 Comments
Post a comment
No comments yet. Be the first to comment!