SLA Technique in Denture Base Fabrication

SLA Technique in Denture Base Fabrication

The stereolithography apparatus (SLA) technique is the most precise and best method for denture base fabrication, as per a recent study published in the Journal of Prosthetic Dentistry.

Conventional fabrication of complete denture metal bases is being replaced by the computer-aided design and computer-aided manufacturing (CAD-CAM) systems. However, a comparative analysis of subtractive and additive CAD-CAM manufacturing techniques is lacking.

The purpose of this in vitro study was to compare the adaptation of complete denture metal bases fabricated by milling (subtractive manufacturing) and stereolithography apparatus (SLA) and digital light processing (DLP) (additive manufacturing).

Thirty metal bases were manufactured by using the milling (MIL group), SLA (SLA group), and DLP (DLP group) techniques. The silicone replica technique was used to evaluate the adaptation of the complete denture metal bases, and 30 silicone blocks were fabricated. The silicone block was cut equally in the canine, first molar, and second molar areas. The gap between the model and the metal base was measured by using a digital microscope at the 3 locations, and the measured data were statistically analyzed by using a statistical software program (α=.05).

Results

The gaps measured at the 3 areas showed significant differences in all 3 groups (P<.05). At the anterior, middle, and posterior areas, the SLA group showed the narrowest gap (302 ±31 μm, 241 ±39 μm, 201 ±43 μm, respectively). The SLA group also had the narrowest total gap of the metal bases (218 ±33 μm).

Thus, the researchers concluded that the adaptation of the fabricated metal bases varied significantly across the techniques used but fell within a clinically allowable range. The SLA group was the most precise in the fabrication of complete denture metal bases. Further studies are required to analyze the effects of the layer thickness setting, wax elimination, and casting temperature on the adaptation of metal bases manufactured by using SLA.

Reference

Evaluation of the adaptation of complete denture metal bases fabricated with dental CAD-CAM systems: An in vitro study by Seung-Gyu You et al. published in The Journal of Prosthetic Dentistry.

https://doi.org/10.1016/j.prosdent.2020.01.039

Disclaimer: This website is designed for healthcare professionals and serves solely for informational purposes.
The content provided should not be interpreted as medical advice, diagnosis, treatment recommendations, prescriptions, or endorsements of specific medical practices. It is not a replacement for professional medical consultation or the expertise of a licensed healthcare provider.
Given the ever-evolving nature of medical science, we strive to keep our information accurate and up to date. However, we do not guarantee the completeness or accuracy of the content.
If you come across any inconsistencies, please reach out to us at admin@doctornewsdaily.com.
We do not support or endorse medical opinions, treatments, or recommendations that contradict the advice of qualified healthcare professionals.
By using this website, you agree to our Terms of Use, Privacy Policy, and Advertisement Policy.
For further details, please review our Full Disclaimer.

0 Comments

Post a comment

Please login to post a comment.

No comments yet. Be the first to comment!