Exposure To Aerosols Can Be Reduced With A Drape, HVE, And Extra Oral Suction In Dentistry
- byDoctor News Daily Team
- 26 July, 2025
- 0 Comments
- 0 Mins
The use of a surgical microscope and bag barrier drape, HVE, and extraoral suction device result in the lowest concentration of aerosolized particles, according to a recent study published in the Journal of the American Dental Association.
The COVID-19 pandemic has increased the importance of minimizing exposure to aerosols generated during dental procedures. The authors' objective was to measure the aerosolized particles in the breathing zone of operators using several facial protection and filtration methods.
Twenty-one dentists performed maxillary anterior incisor veneer preparations using a microscope and drape and loupes with or without a face shield. In each test condition, the following 3 levels of filtration were tested: no filtration, a high-volume evacuator [HVE], and an HVE with an extraoral suction device. Measurements were made using a mass monitor attached to the operator's chest with inlet within 10 inches of the operator's face.
The results of the study are:
The authors found that the microscope and drape provided the lowest levels of aerosolized particles compared with loupes with or without a face shield (P < .001). There was no detectable difference in the concentration of particles between operators wearing a face shield and wearing loupes alone (P = .47). The particles in each test condition were lowered when an HVE was used (P < .001) and further lowered with an extraoral suction device.
Thus, the findings of this study suggest that the use of a surgical microscope and bag barrier drape, HVE, and extraoral suction device result in the lowest concentration of aerosolized particles. The face shield did not appear to offer any protection from aerosolized particles. HVE and extraoral suction were effective in decreasing aerosols regardless of the type of facial protection used. Dentists can reduce exposure to aerosols with a drape, HVE, and extraoral suction.
Reference:
Effectiveness of barrier devices, high-volume evacuators, and extraoral suction devices on reducing dental aerosols for the dental operator: A pilot study by Wayne David Remington, et al. published in The Journal of the American Dental Association.
DOI: https://doi.org/10.1016/j.adaj.2021.08.011
Keywords:
The Journal of the American Dental Association, microscope, drape, aerosolized particles, microscope and bag barrier drape, HVE, and extraoral suction device, COVID-19, surgical microscope, Wayne David Remington, Brian Chandler Ott, Thomas Ryan Hartka,
Disclaimer: This website is designed for healthcare professionals and serves solely for informational purposes.
The content provided should not be interpreted as medical advice, diagnosis, treatment recommendations, prescriptions, or endorsements of specific medical practices. It is not a replacement for professional medical consultation or the expertise of a licensed healthcare provider.
Given the ever-evolving nature of medical science, we strive to keep our information accurate and up to date. However, we do not guarantee the completeness or accuracy of the content.
If you come across any inconsistencies, please reach out to us at
admin@doctornewsdaily.com.
We do not support or endorse medical opinions, treatments, or recommendations that contradict the advice of qualified healthcare professionals.
By using this website, you agree to our
Terms of Use,
Privacy Policy, and
Advertisement Policy.
For further details, please review our
Full Disclaimer.
Tags:
Recent News
Eli Lilly plans to build new USD 3 billion facilit...
- 04 November, 2025
Rajkot Maternity Hospital CCTV Leak: How a simple...
- 04 November, 2025
Gland Pharma profit rises 12 percent to Rs 184 cro...
- 04 November, 2025
AIIMS Delhi doctors told to use Hindi in prescript...
- 04 November, 2025
Daily Newsletter
Get all the top stories from Blogs to keep track.
0 Comments
Post a comment
No comments yet. Be the first to comment!